On 03/05/2014 10:04 AM, Fabio wrote: > Hi Bert, thank you for your answer. > > I can confirm that the 189 uses the same "QM" command as the 187: > <-- QM\r > --> QM,+03.225 mV AC > > The fluke189 is working now, after one more minor modification of the code:
Thanks for your patch, I've merged it. Now if somebody with a Fluke 289 comes along, I can finally consider that driver complete. Anyone? :-) -- Bert Vermeulen [email protected] email/xmpp ------------------------------------------------------------------------------ Subversion Kills Productivity. Get off Subversion & Make the Move to Perforce. With Perforce, you get hassle-free workflows. Merge that actually works. Faster operations. Version large binaries. Built-in WAN optimization and the freedom to use Git, Perforce or both. Make the move to Perforce. http://pubads.g.doubleclick.net/gampad/clk?id=122218951&iu=/4140/ostg.clktrk _______________________________________________ sigrok-devel mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/sigrok-devel