Hi Gwenhael,

On Sun, Apr 30, 2017 at 03:57:40PM +0200, Gwenhael Goavec-Merou wrote:
> From: Gwenhael Goavec-Merou <gwenhael.goavec-me...@trabucayre.com>
> 
> With trigger enabled, and with pulseview, a second (or more) acquisition start
> immediatly instead of blocking. It's mandatory to try several times to have a
> correct behavior.
> 
> According to http://mygizmos.org/ols/Logic-Sniffer-FPGA-Spec.pdf section 2.3.1
> p.8, the openbench logic sniffer must be reset before each arm command.
> 
> This patch may fix bug #809

It still does :) For both patches:

Tested-by: Wolfram Sang <w...@the-dreams.de>

And from a maintenance point of view, I prefer the seperate function, so
for both patches also:

Reviewed-by: Wolfram Sang <w...@the-dreams.de>

Thanks for doing this!

Regards,

   Wolfram