Hi,

On Tue, Aug 15, 2017 at 02:08:54PM +0100, PlusNet wrote:
> However when I select a  meter function that makes use of the dual display
> and select just one channel, sigrok still returns data for BOTH channels:

Thanks for the report. This was a bug / missing feature in the
brymen-bm86x indeed and has been fixed now. Please retry the latest git
libsigrok and verify that it works as expected now. Thanks!


> sr: usb: Failed to open device: LIBUSB_ERROR_ACCESS.
> Failed to open device.
> 
> I am assuming at the moment that this is intended by design or I need to set
> permissions somewhere but I'm not sure where at the moment?

Yup, this is normal. Check libsigrok's README.devices for details. On
Linux you can use the provided udev rules file to handle the permissions
(depending on distro etc. you might want to edit it, but it's usually
not required).


Cheers, Uwe.
-- 
http://hermann-uwe.de | http://randomprojects.org | http://sigrok.org

------------------------------------------------------------------------------