Hello Aleksander, this FIX the problem !!
Am Wed, 4 Apr 2018 23:18:24 +0300 schrieb Aleksander Alekseev <afis...@gmail.com>: > Hello Jörg, > > That works for me: > > sigrok-cli --driver dreamsourcelab-dslogic --config > 'voltage_threshold=1.6-1.6:samplerate=10MHz:continuous=on' > --continuous > > I believe it's all about continuous=on option. The solution was found > here: > > https://sigrok.org/wiki/DreamSourceLab_DSLogic > > On Wed, Apr 4, 2018 at 2:26 PM, Jörg <jalp...@gmx.net> wrote: > > > Hello Aleksander, > > > > If Dslogic is still waiting for a trigger. Which trigger condition > > has been defined by "--continuous"? > > > > Because the identical call works on the Logic16 > > > > Jörg > > > > > > > > Am Wed, 4 Apr 2018 13:03:46 +0300 > > schrieb Aleksander Alekseev <afis...@gmail.com>: > > > > > Hello Jörg, > > > > > > I could be wrong, but it's my understanding that flashing green > > > LED means that DSLogic waits for a trigger condition and doesn't > > > send any data. > > > > > > > > > > > > > > > > > > > > > > > > ------------------------------------------------------------------------------ Check out the vibrant tech community on one of the world's most engaging tech sites, Slashdot.org! http://sdm.link/slashdot _______________________________________________ sigrok-devel mailing list sigrok-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/sigrok-devel