Hello Aleksander,

this FIX the problem !!







Am Wed, 4 Apr 2018 23:18:24 +0300
schrieb Aleksander Alekseev <afis...@gmail.com>:

> Hello Jörg,
> 
> That works for me:
> 
> sigrok-cli --driver dreamsourcelab-dslogic --config
> 'voltage_threshold=1.6-1.6:samplerate=10MHz:continuous=on'
> --continuous
> 
> I believe it's all about continuous=on option. The solution was found
> here:
> 
> https://sigrok.org/wiki/DreamSourceLab_DSLogic
> 
> On Wed, Apr 4, 2018 at 2:26 PM, Jörg <jalp...@gmx.net> wrote:
> 
> > Hello Aleksander,
> >
> > If Dslogic is still waiting for a trigger. Which trigger condition
> > has been defined by "--continuous"?
> >
> > Because the identical call works on the Logic16
> >
> > Jörg
> >
> >
> >
> > Am Wed, 4 Apr 2018 13:03:46 +0300
> > schrieb Aleksander Alekseev <afis...@gmail.com>:
> >
> > > Hello Jörg,
> > >
> > > I could be wrong, but it's my understanding that flashing green
> > > LED means that DSLogic waits for a trigger condition and doesn't
> > > send any data.
> > >
> >
> > > >
> > >
> > >
> > >
> >
> >
> 
> 


------------------------------------------------------------------------------
Check out the vibrant tech community on one of the world's most