On Thu, May 21, 2020 at 07:50:21PM +0200, Soeren Apel wrote: > Hello Phill, > > PulseView only supports logic analyzers and oscilloscopes at this time, > which is why other drivers are filtered out as you noticed. > > If you want to use a DMM with a graphical interface, I suggest using > either > https://sigrok.org/wiki/Sigrok-meter > or > https://sigrok.org/wiki/SmuView
And for command-line usage you can use sigrok-cli: $ sigrok-cli -d va-va18b:conn=/dev/ttyUSB0 --samples 2 P1: 0 mV DC AUTO P1: 0 mV DC AUTO Cheers, Uwe. -- http://hermann-uwe.de | http://randomprojects.org | http://sigrok.org _______________________________________________ sigrok-devel mailing list sigrok-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/sigrok-devel