On Tue, 2020-09-29 at 18:16 +0200, Michael Stapelberg wrote: > > By the way: in your screenshot, I see that you seem to have loaded > my 2020-09-27-anlern-02-klingel-PUR-filtered.srzip into pulseview, > but when I try to do that and add the UART decoder, > the decoder reports the following error: > > srd: Traceback (most recent call last): > File "/usr/share/libsigrokdecode/decoders/uart/pd.py", line 517, in decode > raise SamplerateError('Cannot decode without samplerate.') > uart.pd.SamplerateError: Cannot decode without samplerate. > > Is there a trick you used to correct the samplerate?
Well, I cheated and specified the 500k samplerate in the archive's metadata before opening it in the application. In fact I assumed that you were well aware of the trick -- the ".srzip" name and content looked like handcrafted to me. :) Never got the idea that _not_ having a samplerate would be the normal condition, after your initial capture must have had one, and all the import formats support a respective option when the file content lacks the information. :-] virtually yours Gerhard Sittig -- If you don't understand or are scared by any of the above ask your parents or an adult to help you. _______________________________________________ sigrok-devel mailing list sigrok-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/sigrok-devel