Attached to this email is a patch adding support to the aforementioned 
multimeter. This was easy to do since it's using the already implemented FS9721 
protocol.

Thanks a lot for your software!

Marco.


>From 2cc4819ba760c71bccb0b01ac7a9fb593580c286 Mon Sep 17 00:00:00 2001
From: Marco Rodolfi <marco.rodo...@tuta.io>
Date: Sat, 11 Jan 2025 14:20:51 +0100
Subject: [PATCH] Add support for HoldPeak HP-90EPC multimeter.

This works fine just by using a standard configuration for FS9721 based multimeters.
---
 src/hardware/serial-dmm/api.c | 7 +++++++
 1 file changed, 7 insertions(+)

diff --git a/src/hardware/serial-dmm/api.c b/src/hardware/serial-dmm/api.c
index b271b81c..54bc792e 100644
--- a/src/hardware/serial-dmm/api.c
+++ b/src/hardware/serial-dmm/api.c
@@ -484,6 +484,13 @@ SR_REGISTER_DEV_DRIVER_LIST(serial_dmm_drivers,
 		sr_fs9721_packet_valid, sr_fs9721_parse,
 		sr_fs9721_10_temp_c
 	),
+	DMM(
+		"holdpeak-hp-90epc", fs9721,
+		"HoldPeak", "HP-90EPC", "2400/8n1",
+		FS9721_PACKET_SIZE, 0, 0, NULL,
+		sr_fs9721_packet_valid, sr_fs9721_parse,
+		sr_fs9721_10_temp_c
+	),
 	DMM(
 		"mastech-ms8250b", fs9721,
 		"MASTECH", "MS8250B", "2400/8n1/rts=0/dtr=1",
-- 
2.48.0

_______________________________________________
sigrok-devel mailing list
sigrok-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/sigrok-devel

Reply via email to