TO: Old hand CS-ers and Chemistry types;
First, the history:
I make 2gal.+ batches using 1ma DC and 60" of wetted #14, .999 silver
wire. I normally stop when I get about 20ppm on the PWT.
This time I stopped at 15 because I didn't want to let run overnight.
The next morning I restarted the batch. So far so good. But then, I
developed a splitting headache and completely forgot the batch.
I remembered it eight hours later. It was over 25 on the PWT., it was
clear with a hint of yellow, had a fine tyndel with a few sparkles.
NOW THE KICKER:
I thought to add H2O2 to create mostly ionic silver. But when I added
1oz of H2O2, the batch turned a milky gray-white.
Did I use too much H2O2? and what did I make? (other than a mess).
TIA;
Bruce A.
--
The Silver List is a moderated forum for discussing Colloidal Silver.
Instructions for unsubscribing are posted at: http://silverlist.org
To post, address your message to: [email protected]
Address Off-Topic messages to: [email protected]
The Silver List and Off Topic List archives are currently down...