Hi Bob or CS experts, Susan here, EE. You mention 35ppm--how--are you using 27V LVDC?
Question for you. OK, so I've made my CS using silver from Marsha online and I didn't switch the electrodes. Started with a pint jar. But I've made 1 quart in a glass jar at a time--I've made a couple gallons so far. When done, it is faint yellow (clear) with lots of feathering and eventually major black crud on an electode (negative I believe--can't recall). The next AM it is clear dark gold. I let it go until 6-6.5mA per my meter (not current limited). I kept stirring it until it was consistently 6.5mA--took over an hour. It stains the jar. Anyway, I took this silver and it did nothing compared to the 30ppm Source Natural that has been helping. I could tell in a major way the two weeks I tried it. So I need to figure how to make it better--it appears a bit useless in the form that I am making it. So what am I doing wrong? Is it that I am not switching the electrodes? Need more pure silver? Too much water at a time? Not pure enough distilled H20? (Know a good brand?) Do I stir it or just let it go until concentration at the 6.5mA is between the 1" electrodes? The electrodes are 5", submersed 4" and 1" apart. Do I need to current limit it? If so, how is best? Rheostat or resistor or ? My electrodes are black when I wipe them on a tissue--and I definitely have to strain with coffee filter due to the black particles from the one electrode. Any idea why the dark gold after 8 hours? Does that indicate large particle size? My doctor claimed he makes it by leaving it only 5 minutes, LVDC---????sounds awfully short. Mine doesn't start feathering for 15-20 min. Thanks for your help, Susan L In a message dated 99-07-23 20:05:20 EDT, you write: << Hi Ya'all; "Ole Bob" hasn't been on the net much to post just developing a new CS Gen and reading all of the wierd and wonderful things being posted. In the process of developing my polarity switching generator several very interesting things have materialized. With good water and good silver, polarity switching makes colorless CS up to at least 35 ppm (26 hours), with no cleaning, treeing, and very little sludge. Notice that "good silver" is in italics and underlined. During the development stage I needed to make some new electrodes and used a new lot of silver. With good silver the electrodes are a mouse gray but these turned to coal black. When questioning the supplier I found out that they had shipped sterling silver. Besides having black electrodes the CS after three hours was developing a faint hint of color. It just maybe that a lot of the color problems that you CSers are having is not using five nine silver. The second problem is could very easily come from not having a stable process nor monitoring the current during the formation. A simple battery and bulb system requires a lot of close monitoring to get a reliable and repeatable product. I expect a lot of flack, but how much data have you recorded in your CS making? I have hundreds of sheets of curves generated during the developmental process. And since I make my own spectrophotometeric measurements, and conductive measurements. I know what I have and what the polarity reversal will do. I have it down to "fill and brew." Time it with a commercially available lamp timer. Robert >> -- The silver-list is a moderated forum for discussion of colloidal silver. To join or quit silver-list or silver-digest send an e-mail message to: [email protected] -or- [email protected] with the word subscribe or unsubscribe in the SUBJECT line. To post, address your message to: [email protected] List maintainer: Mike Devour <[email protected]>