----- Original Message ----- From: Marshall Dudley <[email protected]> To: <[email protected]> Sent: Thursday, 9 December 1999 03:07 Subject: Re: CS>RE:Particle size -LV and HV
> > I believe that the smaller particles make it far away from the electrode > at the high voltage and 1/120 of a second to mostly not get pulled back > in. The larger particles don't diffuse very far and likely do get pulled > back to the electrode, to get redeposited as silver, for another try next > cycle. This is why I believe that the particle size profile on HVAC tends > to be for much smaller particles than with the LVDC systems. The larger > ones get recycled. > > Marshall Hi Marshall, My take on this is that the larger particles found in *some* LVDC systems come from the accumulation of metallic silver at the cathode finding its way into the solution. It is my view that the silver leaves the anode as single ions in all systems, and the process of aggregation begins after the power is withdrawn. Ivan. -- The silver-list is a moderated forum for discussion of colloidal silver. To join or quit silver-list or silver-digest send an e-mail message to: [email protected] -or- [email protected] with the word subscribe or unsubscribe in the SUBJECT line. To post, address your message to: [email protected] Silver-list archive: http://escribe.com/health/thesilverlist/index.html List maintainer: Mike Devour <[email protected]>