Dan wrote: > Looking for any information on a hvac silver generator, any type of hvac. > Is there any websites that would help me? What about the flyback > transformer in TV sets?
Neon sign transformers are the most often used because they have a current limited secondary winding. Secondary current ratings of 30 ma and 60 ma are used at voltages between 10,000 and 15,000 volts. Some use 9K volts at 30 ma. A schematic is not really needed. The primary connects to 120v AC usually through a timer switch. The secondary connects to the silver electrodes. Most of the unique designs are concerned with the electrode configuration, geometry and spacing. It is probably easiest to find a unit and look at it to see how they are constructed. frank key -- The silver-list is a moderated forum for discussion of colloidal silver. To join or quit silver-list or silver-digest send an e-mail message to: [email protected] -or- [email protected] with the word subscribe or unsubscribe in the SUBJECT line. To post, address your message to: [email protected] Silver-list archive: http://escribe.com/health/thesilverlist/index.html List maintainer: Mike Devour <[email protected]>