Hear ye, hear ye all newbies et al, In my four years of investigation of various protocols for making CS I have made and data logged over 400 runs of CS, using voltages from 12 v dc to 380 v dc, 780 v ac to 15,000 v ac. I test every batch with my spectrophotometer.
All of this is to say that I have just tested three batches of CS made using Dr. Jon's process, and the results are not very good. So if you are using the process listen-up! Test #1, 5 hrs., conductivity = 30 uS/cc, PPM = 1.1, xtal, clear, very weak T.E. with few sparkles. Test #2, 3 hrs., conductivity =10 uS/cc, PPM = 0.42, xtal clear, very weak T.E. with few sparkles. Test #3, 1 hr., conductivity = 15 uS/cc, PPM = 0.84, xtal clear, very weak T.E. with few sparkles. The inversion of test data for #2 and #3 says that the process is not in control. If you are using Dr. Jon's process or thinking about it, then forget it. With only 6 volts one cannot get the current necessary to do a good job in a reasonable time frame. "Ole Bob" -- The silver-list is a moderated forum for discussion of colloidal silver. To join or quit silver-list or silver-digest send an e-mail message to: [email protected] -or- [email protected] with the word subscribe or unsubscribe in the SUBJECT line. To post, address your message to: [email protected] Silver-list archive: http://escribe.com/health/thesilverlist/index.html List maintainer: Mike Devour <[email protected]>