Hi Ya'all,

I have just finished a 24 hour run using Steve Young's LM334Z regulator
and it works like a champ, and it is rock solid.

I will attach the Wplot data. those that have the Wplot16 or 32 can look
at the curves, all others can open the file with your notepad.

Briefly, I set up as near to Steve's process as possible and monitored
cell voltage, cell current and conductivity during the run, and withdrew
two 1 cc samples during the brew to test for PPM (true) and the final
PPM.

At the 8 hr. point Ag+ = 6.16 PPM, At the 17 hr. point Ag+ = 10.56 PPM
The final conc. after stirring the brew is 11.66 PPM.

This process is very susceptible to any motion. I may repeat it with
mechanical stirring.

To give you an example of how your PWT will fool you the conductivity at
the end after stirring was 79.3 uS/cm. and the conc. is 11.66 PPM.

"Ole Bob"


Attachment: Steve Young.PLT
Description: application/unknown-content-type-plt_auto_file