Rich, This procedure doesn't re-establish the factory defaults. It is one of those flawed designs that occasionally slip through to cut costs with unexpected consequences. The 90L and 90L+ are the only Decservers with no reset to factory defaults capability. The follow on product, the 90TL has a reset button.
Sincerely, Robert F. Thomas 44 Industrial Way Norwood, MA USA 02062 N Office Phone - (781) 329-9200 O mail to: [email protected] -----Original Message----- From: Rich Alderson [mailto:[email protected]] Sent: Tuesday, April 12, 2016 4:11 PM To: Robert Thomas <[email protected]> Cc: [email protected] Subject: Re: [Simh] Setting DECSERVER 90L to factory defaults http://manx.classiccmp.org/collections/mds-199909/cd2/network/dsrvdom1.pdf > From: "Robert Thomas" <[email protected]> > Date: Tue, 12 Apr 2016 15:47:00 -0400 > I know that this is off topic, but we do communicate with Decservers > from the SIMH microvax simulator. We bought a replacement > DECserver-90L and it is set with non-standard passwords, so it is unusable. > Anyone know how to force a factory reset? There is no reset button. http://manx.classiccmp.org/collections/mds-199909/cd2/network/dsrvdom1.pdf Pages 40-41 in the PDF (pages 4-13 and 4-14 of the DECserver 90L user manual). You need physical access to the 90L, because you have to power cycle it to change from Authorized (uses passwords) to not. Rich _______________________________________________ Simh mailing list [email protected] http://mailman.trailing-edge.com/mailman/listinfo/simh