Hi, may be someone could describe "the EEPROM desoldering" way?
Thank you in advance! Best regards, Sergii On Wednesday, 13 April 2016, Broer van Smeden <[email protected]> wrote: > Hi Robert, > Consider to throw the DECSERVER 90L away, This is a nasty piece of > hardware, which behavior is quit different compared to 90TL or 90M, the > latest does also support IP setup. > Please consider to use a DS700-16 or a DS700-32, which let you to connect > via UTP. > At the end of this year, I might supply you with old hardware. > > Kind regards, > Broer > > 2016-04-13 2:07 GMT+02:00 Robert Thomas <[email protected] > <javascript:_e(%7B%7D,'cvml','[email protected]');>>: > >> Rich, >> >> This procedure doesn't re-establish the factory defaults. It is one of >> those flawed designs that occasionally slip through to cut costs with >> unexpected consequences. The 90L and 90L+ are the only Decservers with no >> reset to factory defaults capability. The follow on product, the 90TL >> has a >> reset button. >> >> Sincerely, >> Robert F. Thomas >> >> 44 Industrial Way >> Norwood, MA USA 02062 >> N Office Phone - (781) 329-9200 >> O mail to: [email protected] >> <javascript:_e(%7B%7D,'cvml','[email protected]');> >> >> >> >> -----Original Message----- >> From: Rich Alderson [mailto:[email protected] >> <javascript:_e(%7B%7D,'cvml','[email protected]');>] >> Sent: Tuesday, April 12, 2016 4:11 PM >> To: Robert Thomas <[email protected] >> <javascript:_e(%7B%7D,'cvml','[email protected]');>> >> Cc: [email protected] >> <javascript:_e(%7B%7D,'cvml','[email protected]');> >> Subject: Re: [Simh] Setting DECSERVER 90L to factory defaults >> >> http://manx.classiccmp.org/collections/mds-199909/cd2/network/dsrvdom1.pdf >> > From: "Robert Thomas" <[email protected] >> <javascript:_e(%7B%7D,'cvml','[email protected]');>> >> > Date: Tue, 12 Apr 2016 15:47:00 -0400 >> >> > I know that this is off topic, but we do communicate with Decservers >> > from the SIMH microvax simulator. We bought a replacement >> > DECserver-90L and it is set with non-standard passwords, so it is >> unusable. >> >> > Anyone know how to force a factory reset? There is no reset button. >> >> http://manx.classiccmp.org/collections/mds-199909/cd2/network/dsrvdom1.pdf >> >> Pages 40-41 in the PDF (pages 4-13 and 4-14 of the DECserver 90L user >> manual). >> >> You need physical access to the 90L, because you have to power cycle it to >> change from Authorized (uses passwords) to not. >> >> Rich >> >> _______________________________________________ >> Simh mailing list >> [email protected] >> <javascript:_e(%7B%7D,'cvml','[email protected]');> >> http://mailman.trailing-edge.com/mailman/listinfo/simh >> > >
_______________________________________________ Simh mailing list [email protected] http://mailman.trailing-edge.com/mailman/listinfo/simh