Robert Chen wrote:

[ Moved to SIP Implementors ]

> What should the proxy server do if we never get the BYE message?

Depends on what is the statefullness of the proxy; a stateless proxy could
care less if it got a BYE or not; ditto for a  transaction-stateful proxy.
A call-stateful proxy may maintain resources until it gets a BYE, so this
is probably the case of interest to you.

> If neither UA will end the call with a BYE message, how can the proxy 
> server know?

Call stateful proxies may support the session timer extension (see
http://search.ietf.org/internet-drafts/draft-ietf-sip-session-timer-04.txt)
  
> Only SIP gateway contact with Radius server is meanful? A proxy server
> contact with Radius server is meanless?

Not really; depending on what is it that you want the proxy to do.  For
instance, if the proxy is executing some services on behalf of the user,
it may use RADIUS to authenticate/authorize the user (see
http://search.ietf.org/internet-drafts/draft-sterman-sip-radius-00.txt)

- vijay
--
Vijay K. Gurbani  vkg@{lucent.com,research.bell-labs.com,acm.org}
Internet Software and eServices Group 
Lucent Technologies/Bell Labs Innovations 263 Shuman Blvd., Rm 1A-413
Naperville, Illinois 60566     Voice: +1 630 224 0216   Fax: +1 630 713 0184
_______________________________________________
Sip-implementors mailing list
[EMAIL PROTECTED]
http://lists.cs.columbia.edu/mailman/listinfo/sip-implementors