I do not think the RFC stipulates any sequence.  What you are doing is
valid.  May be you can make the 183 reliable and see if the phones support
it.

-----Original Message-----
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED]]On Behalf Of Volety,
Suryaprakash Rao (Prakash)
Sent: Wednesday, January 22, 2003 9:49 PM
To: '[EMAIL PROTECTED]'
Subject: [Sip-implementors] 18x response sequence


I bumped into this problem the other day relating to sequencing of 180
Ringing  and 183 Session Progress responses from UAS.

In the following call flow  (with either  Cisco  7960 or  Pingtel) User
Agent Client  is  ignoring 183 and thereby failing to provide early media.

  SIP UAC                                   UAS
---INVITE---->
....            <-----------------  100 Trying
                 <--------------- 180 Ringing
                 <--------------- 183 Session Progress


However if we send , from UAS,  183  followed by  and 180 responses  , then
UAC is  providing early media.
Can someone tell me what should be the exact sequence of responses that RFC
stipulates ?

Thanks,
Prakash

_______________________________________________
Sip-implementors mailing list
[EMAIL PROTECTED]
http://lists.cs.columbia.edu/mailman/listinfo/sip-implementors