Hi, if a UAC sends a SUBSCRIBE and the proxy does parallel forking to
two servers, it could occur that both servers reply a 200.

Should the proxy relay the second 200 to the UAC? or should it absorb it?

Anyhow I do know that the UAC must be ready to receive an in-dialog
NOTIFY with an unknown Totag (the NOTIFY generated by the second
server) so the UAC should generate a second subscription dialog then
and should manage it (as RFC 6665 mandates).

Thanks a lot.

-- 
Iñaki Baz Castillo
<[email protected]>

_______________________________________________
Sip-implementors mailing list
[email protected]
https://lists.cs.columbia.edu/cucslists/listinfo/sip-implementors