Hi all, I recently ran into an intro issue with some unknown SIP device. My client uses a per-stream SDP connection line, but when a stream is disabled (port set to 0) the stream is just reduced to the m= line.
Technically I could put the connection line at the session level in some cases, but it could be that I need to have it at the stream level. Should I also add it for disabled streams? FWIW, doing so made the aforementioned SIP device happy, but I couldn’t find any RFC reference which stated it’s always required. Any clarification (or recommendation) would be appreciated, thanks! -- Saúl Ibarra Corretgé AG Projects
_______________________________________________ Sip-implementors mailing list Sip-implementors@lists.cs.columbia.edu https://lists.cs.columbia.edu/mailman/listinfo/sip-implementors