Hi All,
I found out how to get a different port number: just need to use the option
-t un
Khaldon
2008/8/13 ims.asuser ims.asuser <[EMAIL PROTECTED]>
> Hi,
>
> Thanks for your reply.
>
> As I am running UASs and UACs on two computers, the registering port has to
> be different in order to differentiate the users. 2 users can not receive a
> call on the same port at the same time. That's the big issue...
>
> I am wondering how all of you gave tested their systems (how many PCs,
> users...)?
>
> Cheers
> Khaldon
>
> 2008/8/13 Tu Le Van <[EMAIL PROTECTED]>
>
> Hi Khaldon,
>>
>> You can tried this.
>>
>> *Register xml files:*
>>
>> <send retrans="500">
>> <![CDATA[
>> REGISTER sip:[field2] SIP/2.0
>> Via: SIP/2.0/[transport] [field0]:*5062*;branch=[branch]
>> Call-ID: [call_id]
>> Contact: <sip:[EMAIL PROTECTED]:*[field4]*>
>> CSeq: [cseq] REGISTER
>> From: <sip:[EMAIL PROTECTED]>;tag=[call_number]
>> Supported: timer
>> To: <sip:[EMAIL PROTECTED]>
>> Max-Forwards: 70
>> Expires: [field3]
>> User-Agent: iPDialog Phone
>> Content-Length: 0
>> ]]>
>>
>> [field4] is 5060.
>>
>> In my case, I can run Register script on port 5062 and leave port 5060
>> for UAC or UAS script. And don't change 5062 to [local_port], you need to
>> hardcode this parameter. I don't know the reason why but if you change this,
>> SIPp will use port 0 instead of [local_port]
>>
>> Hope this will help you.
>>
>> Regards,
>>
>> ------------------------------
>> *From:* [EMAIL PROTECTED] [mailto:
>> [EMAIL PROTECTED] *On Behalf Of *ims.asuser
>> ims.asuser
>> *Sent:* Wednesday, August 13, 2008 4:39 PM
>> *To:* [email protected]
>> *Subject:* [Sipp-users] Configuration+port
>>
>> Hi all,
>>
>> I would like to test the OpenIMSCore.
>> My configuration is:
>> - 2 PCs running SIPp (1 for UACs and 1 for UASs)
>> - 1 PC running OpenIMSCore
>>
>> The thing is that I want to make 100 simultaneous calls. For that, I need
>> to use different ports for each (as everything is running on the same
>> machine) . But when I register my users, SIPp put the same port for all
>> users, so it is impossible to make simultaneous port.
>>
>> I am using these commands:
>> 1) UASs machine
>> ./sipp -sf ims_reg.xml 192.168.3.7:4060 -i 192.168.3.9 -m 20 -inf
>> reguas.csv
>> ./sipp -sf ims_uas.xml 192.168.3.7:4060 -i 192.168.3.9 -m 18 -inf uas.csv
>>
>> 2) UACs machine
>> ./sipp -sf ims_reg.xml 192.168.3.7:4060 -i 192.168.3.9 -m 20 -inf
>> reguac.csv
>> ./sipp -sf ims_uac.xml 192.168.3.7:4060 -i 192.168.3.9 -m 18 -inf uac.csv
>>
>>
>> What I want is when I register several users, I want SIPp to do it with
>> different port so that I can make several calls on the same time.
>> Has anyone already experienced that?
>>
>> Thank you
>> Khaldon
>>
>
>
-------------------------------------------------------------------------
This SF.Net email is sponsored by the Moblin Your Move Developer's challenge
Build the coolest Linux based applications with Moblin SDK & win great prizes
Grand prize is a trip for two to an Open Source event anywhere in the world
http://moblin-contest.org/redirect.php?banner_id=100&url=/
_______________________________________________
Sipp-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/sipp-users