Hi

With this setup:

uac <---> App <--> uas

The SIPp 3PCC mode with the sendCmd and recvCmd can be used to exchange 
out-of-band information between uas and uac if the App under test is a SIP 
Proxy, where the Call-ID is unmodified and thus known by both uas and uac SIPp 
processes.

But when testing a B2BUA Application, the Call-ID on the uas side of the B2BUA 
is not known on the uac side.
Are there any known tricks to synchronize these two SIPp processes? 


E.g. many B2BUAs copy unknown headers, so if the uac adds a custom SIP header 
with a correlationID, this would propagate to the uas, and could be used to 
correlate the recvCmd. Another idea would be if the uas added the Call-ID in a 
shared file, which the uac could read the Call-ID for the nth call on the nth 
line.


Best regards
Henrik Leion


------------------------------------------------------------------------------