On 21 January 2014 22:25,  <henrik.le...@tieto.com> wrote:
> The SIPp 3PCC mode with the sendCmd and recvCmd can be used to exchange 
> out-of-band information between uas and
> uac if the App under test is a SIP Proxy, where the Call-ID is unmodified and 
> thus known by both uas and uac SIPp processes.
> But when testing a B2BUA Application, the Call-ID on the uas side of the 
> B2BUA is not known on the uac side.
> Are there any known tricks to synchronize these two SIPp processes?

Hi Henrik,

At the moment, the Call-ID is the only thing that's supported - you're
right that that's not very useful for B2BUAs, and being able to
correlate 3PCC on something else (like a custom header) would be
useful.

What are you trying to accomplish with this 3PCC setup? I'm wondering
whether there's another way to achieve your goals without using 3PCC.

Best,
Rob

------------------------------------------------------------------------------