On Fri, 2008-11-21 at 20:11 +0530, Ananda Teertha wrote:
> Hi All,
> 
> Following is one of the scenario that is covered for CDR tests.
> 
> Test :
> Make a call from Phone1 to Phone2 and then forward the call to phone3
> from phone2.Answer the call on phone3 and disconnect the call from
> Phone1. Click on Apply button on Calls page.

If by "and then forward the call" you mean that forwarding in sipXecs
was set to forward calls from Phone1 to Phone2, then your expected
result is incorrect - there should be only one call in the CDR.

> Expected result :
> CDR table should have all the call detail records : ie ; a) Call  from
> Phone1 to Phone2
> 
> b) Call  from  Phone1 to Phone3. (Here, established call).
> 
> Actual observation:
> CDR table shows  only one call detail record ; ie; a) Call from Phone
> 1 to Phone2.  
> The same  CDR  continues for case b) also; and there is no CDR for the
> call between Phone1 and Phone 3.
> 
> Please let me know if it is the expected behavior or the bug.
> 
> Thanks
> Venugopal.
> 