On Mon, Feb 9, 2009 at 12:48 PM, Scott Lawrence <[email protected]> wrote: > > On Sun, 2009-02-08 at 11:56 -0500, M. Ranganathan wrote: >> Hello, >> >> Per the requirements of SIPCONNECT, >> I need to support the following behavior in sipx for dialing emergency >> services. >> How can I determine that the outbound call to the ITSP is an emergency call >> based upon the INVITE sent to sipxbridge from the sipx proxy server? > > I think that the requirement can be completely met by proper dial plan > configuration, and does not require any new sipXbridge functionality. > > Confusion (on my part) was cleared up by Scott. It turns out that sip:911;phone-context=+16789901234 is all the USER part of the SIP URI (I had mistaken it for a URL Parameter). There is nothing that needs to be done.
Ranga -- M. Ranganathan _______________________________________________ sipx-dev mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-dev Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-dev