On Fri, 2009-02-20 at 15:46 +0530, Chaitra wrote:
> This is regarding call forwarding an Inbound call from an ITSP to an SCS 
> user or PSTN numbers.
> Consider the following scenario:
> Inbound call made using bandwidth.com terminates on user 200 in SCS who 
> has set a call forwarding (if no response) forward to another PSTN 
> number (ring for 30 seconds)
> Default serial fork expiration = 20

Are we sure that a 1xx response has been sent to the ISP within 32
seconds?

According to the flowchart on page 128 of RFC 3261, the callee has
"Timer B" time to send a 1xx response or the caller can consider the
call timed-out.  According to the table on page 265, the default Timer B
value is 32 seconds.

Dale


_______________________________________________
sipx-dev mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-dev