On Fri, 2009-02-20 at 15:46 +0530, Chaitra wrote: > This is regarding call forwarding an Inbound call from an ITSP to an SCS > user or PSTN numbers. > Consider the following scenario: > Inbound call made using bandwidth.com terminates on user 200 in SCS who > has set a call forwarding (if no response) forward to another PSTN > number (ring for 30 seconds) > Default serial fork expiration = 20
Are we sure that a 1xx response has been sent to the ISP within 32 seconds? According to the flowchart on page 128 of RFC 3261, the callee has "Timer B" time to send a 1xx response or the caller can consider the call timed-out. According to the table on page 265, the default Timer B value is 32 seconds. Dale _______________________________________________ sipx-dev mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-dev Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-dev