Hi all,

I am executing one scenario "SMC monitoring the phone doing directed 
call pick up"

1)First User 400(Monitored phone) dials 500. On work group window, BLF 
entry  against user 400 displayed as below.

Group member   Phone status     Call Type         Remote Type
[400]                Ringing              Outgoing             500

2)Now user 110(Monitored phone) dials *78500.On work group window, BLF 
entry  against user 400  and 110 displayed as below.

Group member   Phone status       Call Type          Remote Type
[400]              * On the phone       Incoming           121*
[110]                On the phone       Outgoing  
       
My query is  though  user 400 is initiator in the beginning when user 
110 dials *78110 Call type for user 400 changes to "Incoming".
Test case says call type for user 400 should be "Outgoing" even after 
user 110 dials *78110.

Please advice me that whether it is a wrong behavior or expected ?


Thanks,
Soumya