I wrote: > I've been looking into XX-5417 - use HTTP instead of TFTP to > manage phones in support of remote workers. ... > 2. Nortel IP 12x0
The Nortel IP 12x0 firmware has been enhanced, and now allows firmware upgrades via HTTP. The updated instructions are: - Navigate to the "Advanced' screen in the Web GUI. - Change the "Provisioning URL" to "http://<server>/phone/profile/tftproot", where "<server>" is the IP or FQDN of the sipXcofig machine. - Leave "HTTP Proxy" main value and "Port" blank. - Ensure the "Auto-config Profile" is set to "Profile-C", same as for TFTP. - Ensure the "Auto-config Path" is set to the default "Nortel/config", same as for TFTP. - Ensure "Auto-config Every Boot" is enabled, which is also the default. - Click "Commit Changes". - Send the profile from sipXconfig. Also, you can optionally add :<port> to cause the phone to send HTTP requests non-default (i.e. not "80") port. This would be useful when the enterprise's public domain is already using port 80 for its web content. The admin will simply setup a firewall rule mapping some unused public port to the sipXecs internal port 80. To get above functionality you need firmware version SIP12x0.01.01.00.00, which was released today. (Note: SIP12x0.01.01.00.00 vs. SIP12x0.01.00.01.00). Thanks. -Paul [email protected] _______________________________________________ sipx-dev mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-dev Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-dev