> -----Original Message-----
> From: M. Ranganathan [mailto:[email protected]] 
> Sent: Monday, June 15, 2009 3:49 PM
> To: Joly, Robert (CAR:9D30)
> Cc: sipx-dev
> Subject: Re: [sipX-dev] Relay free sipxbridge operation for federation
> 
> On Mon, Jun 15, 2009 at 3:31 PM, Robert Joly<[email protected]> wrote:
> >> Hello all!
> >>
> >> There was a thread some time ago about relay free sipxbridge 
> >> operation and recently there has been a thread on sipx 
> federation. I 
> >> wonder what you feel about the following.
> >>
> >> Say you wanted to tie system A and System B together.  System A is 
> >> the "server" in this case and is providing NAT compensation to its 
> >> remote workers. System B can be configured using 
> sipxbridge to look 
> >> like a remote worker to system A.
> >>
> >> Clearly we don't need two media relays between the systems.
> >> If we can support an option to suppress relaying of media, then 
> >> system B looks like a remote worker to system A.
> >>
> >> When a request originates from System B bound for system A via 
> >> sipxbridge, its contact and Via would get re-written but 
> sipxbridge 
> >> would leave the SDP alone.
> >> sipxbridge on system B can  forward REFER after appropriate 
> >> re-writing of the request as it is aware that is talking 
> to another 
> >> sipx system that is capable of handling that REFER.
> >>
> >> It seems to me that this should be relatively easy to support in 
> >> sipxbridge. Will this scheme work in principle, as a possible 
> >> solution for federating systems? If not, what is wrong with this?
> >
> > I'm a bit confused by the description and I'm not sure why 
> you would 
> > want to use sipXbridge to connect two sipXecs systems in the first 
> > place?  We recommend to do this with site-to-site dialplans and the 
> > existing remote-worker solution has mechanisms in place to 
> avoid doing 
> > the double-relaying. What real-world problem are we trying solve?
> 
> It is quite possible that a mechanism already exists and that 
> I just do not understand it so please help me understand :
> 
> When a remote worker phone registered at site A wants to do a 
> call to a phone registered as a remote worker on  Site B, 
> could you please tell me how it would proceed ( what would be 
> the call flow and how do you avoid relaying media twice?).
> 
> 
> 
> Thanks in advance.
> 

The mechanism is described in section 4.5 of
http://code.sipfoundry.org/browse/~raw,r=14975/sipXecs/main/sipXproxy/do
c/NAT-traversal/NAT_Traversal_Design_Doc.doc.  It does not have a call
flow, but I think that the mechanism can be understood from the test