Hi,

I'm taking a look at issues:
  http://track.sipfoundry.org/browse/XX-7342 and
http://track.sipfoundry.org/browse/XX-6944
which relate to the handling of configuration changes for the internal
SBC.

This issue appears to be related to confusion in sipXecs between
sipXbridge's role as a service 
and its role as a device. Currently sipXconfig provides a service to
handle configuration for the 
Internal SBC, but the Internal SBC is also treated as a device.

In configuration when we do a "Send Profile" to the Internal SBC it
replicates sipxbridge.xml,
and (after a delay of approx 20 seconds) it reports the device
"Restarting: sipXbridge-1/Internal SBC" 
in Job Status, which marks the SIP Trunking service "restart required"
(but doesn't actually restart it).
This doesn't seem right, I would expect the "Send Profile" to actually
restart the Internal SBC.

However if you just change Internal SBC configuration (and don't do a
"Send Profile") this also
(after a delay) reports the device "Restarting: sipXbridge-1/Internal
SBC" in Job Status, which marks 
the SIP Trunking service "restart required". In this case I would expect
it to not restart the device 
since the installer has not actually sent the profile yet.

In general I would recommend that we should try to make the Internal SBC
behave more like a device, 
and try to avoid the (rather annoying) delayed Restart Required state on
the SIP Trunking service. 
Any comments or suggestions?

Thanks...
Dave.