On Wed, 2010-05-12 at 09:41 -0400, JOLY, ROBERT (ROBERT) wrote:
> > If the pickup redirector sends the SUBSCRIBE to the proxy 
> > using tcp, shouldn't you be able to detect the failure much 
> > faster than 2.5 seconds?
> 
> How long does it take of a socket connection to time out if the other
> end is not responding at all?  I thought that this could take a while.

It depends... if the process at the other end is still there but not
responding (the proxy is wedged but not down), then it can take a long
time.  I don't know how much we can do about that case no matter what.
In the much more common case in which either the server is not at the IP
address or the process is not running, we should get a very quick error
(milliseconds).