yea but the media relay is going to change all media packets outbound to
the static IP set in the NAT settings...

and with most firewalls you need to do a 1-to-1 nat with the outside IP.
 you can't 1-to-1 nat 5080 udp to multiple outside IP's.  this does not
compute.

mike

On Fri, Sep 28, 2012 at 8:17 AM, Gerald Drouillard
<[email protected]>wrote:

> On 9/27/2012 6:58 PM, Michael Picher wrote:
> > how can the 1 server have 2 different outside IP addresses?
> >
> > i don't think sipxbridge / media relay can deal with this.
> It can.  The second IP address would only be used if for whatever reason
> the primary address/connection is going to be down.  We would then go
> into sipx and set the primary public IP address to be the backup.  It
> would be nice sipx would handle dual public IP's automatically but that
> is another subject.  In this case sipx is sending back a 500 on the
> primary about 50% of the time.  I am surprised (pleasantly) that the
> call does connect on the backup IP/ISP even though we didn't switch the
> public IP in sipx.  The backup IP is a domain alias.
>
> The same rules on each ISP connection are used.  The packets are not
> rejected as the capture is taken at the firewall and the 500 response
> comes from sipx.  An identical request later will work. See the packet
> captures in my previous post.
>
> >
> > i'd setup another box with sipxbridge on it also and the different
> > outside IP.  Then do 1-to-1 nat on the firewall from that outside IP
> > to this other box.
> This is not a routing/firewall issue.  I think it is something to do
> with the latest patches.  I noticed this buy accident when investigating
> the ACD overflow not working and leaving the outside caller stranded
> with MOH.
>
> --
> Regards
> --------------------------------------
> Gerald Drouillard
> Technology Architect
> Drouillard & Associates, Inc.
> http://www.Drouillard.biz
>
> _______________________________________________
> sipx-dev mailing list
> [email protected]
> List Archive: http://list.sipfoundry.org/archive/sipx-dev/
>



-- 
Michael Picher, Director of Technical Services
eZuce, Inc.

300 Brickstone Square****

Suite 201****

Andover, MA. 01810
O.978-296-1005 X2015
M.207-956-0262
@mpicher <http://twitter.com/mpicher>
linkedin <http://www.linkedin.com/profile/view?id=35504760&trk=tab_pro>
www.ezuce.com

------------------------------------------------------------------------------------------------------------
There are 10 kinds of people in the world, those who understand binary and
those who don't.
_______________________________________________
sipx-dev mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-dev/

Reply via email to