Hi Nikolay,

thanks for your answer. Of cause I can restart the phone manually, but 
if it has no account data written into its configuration it won't 
register anyway. So the main problem I have is that no configuration 
data (SIP proxy, username/password) is written to the device.

BTW, as far as I know it is possible to restart a Linksys phone by 
calling a special URL (http://<phone-ip-addr>/admin/reboot), so 
generally speaking it is not required for the phone to be registered to 
restart it (if you know its IP address).

Regards,
Andreas


Nikolay Kondratyev schrieb:
> Andreas,
> Sipx is not able to reset a phone until it is registered.
> So first time you need to reset the phone manually.
> After that, phone should get it's configuration and be working.
> Possibly you'd like to look at the network trace during this reboot. It'll
> clarify how the phone gets it's configuration from sipx.
> HTH,
> Nikolay.
> 
>> -----Original Message-----
>> From: [EMAIL PROTECTED] [mailto:sipx-users-
>> [EMAIL PROTECTED] On Behalf Of Andreas Kaufmann
>> Sent: Wednesday, May 28, 2008 7:35 PM
>> To: [email protected]
>> Subject: [sipx-users] Problems provisioning Linkys SPA962
>>
>> Hi,
>>
>> I have problems loading configuration into a Linkys SPA962. Service
>> Status says it has pushed the configuration data into the phone and
>> restarted the device, but when I look into the configuration of the
>> phone using the web browser nothing has changed, especially there is no
>> SIP account information.
>>
>> BTW, the phone is automatically discovered. Any ideas?
>>
>> Thanks,
>> Andreas
>> _______________________________________________
>> sipx-users mailing list
>> [email protected]
>> List Archive: http://list.sipfoundry.org/archive/sipx-users
>> Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users
> 
> 
> 
> 

_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users
Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users