Hi Nikolay, thanks for your answer. Of cause I can restart the phone manually, but if it has no account data written into its configuration it won't register anyway. So the main problem I have is that no configuration data (SIP proxy, username/password) is written to the device.
BTW, as far as I know it is possible to restart a Linksys phone by calling a special URL (http://<phone-ip-addr>/admin/reboot), so generally speaking it is not required for the phone to be registered to restart it (if you know its IP address). Regards, Andreas Nikolay Kondratyev schrieb: > Andreas, > Sipx is not able to reset a phone until it is registered. > So first time you need to reset the phone manually. > After that, phone should get it's configuration and be working. > Possibly you'd like to look at the network trace during this reboot. It'll > clarify how the phone gets it's configuration from sipx. > HTH, > Nikolay. > >> -----Original Message----- >> From: [EMAIL PROTECTED] [mailto:sipx-users- >> [EMAIL PROTECTED] On Behalf Of Andreas Kaufmann >> Sent: Wednesday, May 28, 2008 7:35 PM >> To: [email protected] >> Subject: [sipx-users] Problems provisioning Linkys SPA962 >> >> Hi, >> >> I have problems loading configuration into a Linkys SPA962. Service >> Status says it has pushed the configuration data into the phone and >> restarted the device, but when I look into the configuration of the >> phone using the web browser nothing has changed, especially there is no >> SIP account information. >> >> BTW, the phone is automatically discovered. Any ideas? >> >> Thanks, >> Andreas >> _______________________________________________ >> sipx-users mailing list >> [email protected] >> List Archive: http://list.sipfoundry.org/archive/sipx-users >> Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users > > > > _______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users