On Fri, 2009-01-02 at 11:46 -0200, Roman Rodriguez wrote:
> Scott, than you for the information about this tool.
>  
> Please, could you help me with this issue I have between SCS 500 and
> Huawei?
>  
> I attach the mail with the request.
>  
> 
> PSTN -----> HUAWEI ------> SBC --------> SCS 500 ( user endpoints
> registered 4002 and 4003)
>  
> TEST 1: From PSTN (1155507323) to call 4002 and BLIND Transfer to 4003
> = FAIL 
> TEST 2: From PSTN (1155507323) to call 4002 and CONSULTATIVE Transfer
> to 4003 = FAIL
>  
> REFERENCES:
>  
> SBC IP ADDRESS: 154.0.184.4
> SCS 500 IP ADDRESS: 47.46.139.180
> 4002 NORTEL i1140e USER ENDPOINT: 47.46.139.171
> 4003 LG 6804 USER ENDPOINT: 47.46.139.227  
>  
> Incomming calls from PSTN to any user endpoint SIP works OK.
> Blind and consultative transfer between any user endpoint works OK.
>  
> Transfers (blind and consultative) do not work for calls made from
> PSTN to a user's endpoint SCS 500

The SBC (or perhaps HUAWEI - no way to tell from your trace) is
rejecting the REFER request (frame 3097 in your trace file of the blind
transfer).