Hi all,

I'm still playing around trying to set up call plans and I've hit a
couple of snags.

I have my Sip-X server connecting to a Mediant 1000 gateway, which
currently has a single analogue line plugged in for testing.  The
analogue line is off a Siemens HiCom switch, one of several on site, and
I need to interface with it correctly.  This means that I have to have
4-digit internal extensions and dial a 0 to get an outside line.

I have installed the UK-English localization pack and by simply
activating the standard dial plans I can now dial all the outside stuff
by prefixing it with a 0.  Trying to get it to dial a 4-digit extension
on the HiCom without a prefix is proving difficult however, and my
attempts at a dialplan seem to be failing.

Calls ring out but no hardwired extension rings, and in my active call
logs I have calls showing as either 'in progress' for many days at a
time, or they don't appear in the historic log at all.  Has anyone
successfully set up a rule for dialing 4-digit extensions through a
gateway that doesn't break anything else?  I've tried creating and
altering a local rule, altering a long-distance rule and creating custom
rules, all to no avail.

Kenny Mitchell