Robert, As far as I understand from your trace you can not make a call in siemens -> sipx directions. Looking at you trace one can see, that your Mediant 1000 gateway sends Cancel with "Reason: Q.850 ;cause=102" in 4 seconds after Invite. Q.850 says that cause 102 is related to RES timer expiry. I'm not sure what "RES timer" is.... Looks like Siemens sends "disconnect" with cause 102. And there is something wrong in the siemens-mediant isdn link (is it pri?).
If I were you, I would increase a debug level on the mediant to 5. Then point mediant to a syslog server. Make a call. Try to analyze syslog file. (You can view syslog messages from the mediant web interface, but my experience is that web interface does not show them well...). I can try to take a look at your syslog file... Nikolay. > -----Original Message----- > From: [email protected] [mailto:sipx-users- > [email protected]] On Behalf Of PENZ Robert > Sent: Thursday, February 19, 2009 12:52 PM > To: [email protected] > Subject: [sipx-users] sipx and audiocodes gateway > > Hi! > > I'm evaluating sipx via an Audiocodes gateway to our old Siemens pbx. I'm > able to call via sipx numbers on the Siemens pbx, but it does not work the > other way around. The phone rings 1-2 times and than it stops ringing. If > I pickup in that time I get only silence. > > I've attached a tcpdump trace with these 3 systems. > > 10.10.131.75 audiocodecs gateway > 10.12.142.10 sipxServer > 10.12.142.251 snom phone > > I hope someone can tell me what I'm doing wrong. ;-) > > > Mit freundlichen Grüßen > Robert Penz > > ---------------------------------------------------- > Dipl. Inf. Robert Penz > DVT-Daten-Verarbeitung-Tirol GmbH > Adamgasse 22, 6020 Innsbruck > Tel: +43 512 508 3334 / Fax: +43 512 508 3355 > eMail: [email protected] _______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users