Hi everybody, Take a look at this scenario.
Sipx with two gateways: gateway A is connected to another (traditional) PBX and gateway B is connected to PSTN. The traditinal PBX sends outgoing calls from extension 200 through the gateway A, then Sipx routes calls according its dial plan. In the dial plan there's a rule that routes calls to gateway B, with a Long Distance Dialing permission. So the proxy sends back a 407 SIP message to the gateway A, asking user 200 to authenticate: the gateway doesn't own any authentication credential so the call is dropped. Is there any way to place the call to the gateway B? Thanks, Max _______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users