On Thu, 2009-04-02 at 11:17 -0400, milosz wrote:
> i wonder how easy it would be to
> 
> (1) pull the list of extensions off your pbx and throw them in an
> excel sheet (or something)
> (2) use this list to generate a bunch of insert statements for the
> users table in sipxconfig
> (3) use same list & sip passwords to generate cli statements for patton

No - you misunderstand.  You only need _one_ user, and it does not need
to match that of the pbx extensions.  It is a single identity for the
gateway.

> > If you can get the gateway between your legacy pbx and sipXecs to
> > authenticate itself (that is, configure a user in sipXecs for the
> > gateway and put those credentials in the gateway) it would be much
> > better.  Note that the user you configure does _not_ need to be the same
> > as the identity in the From header for this to work.  The From header
> > can be the extension on the other pbx and the user the gateway
> > authenticates as can be something else entirely - sipXecs doesn't care;
> > all it wants is an identity that has the permission required by the dial
> > plan.  This is a _much_ better approach than removing the permission.
> >
> >
> >
> >