On Thu, 2009-04-02 at 11:17 -0400, milosz wrote: > i wonder how easy it would be to > > (1) pull the list of extensions off your pbx and throw them in an > excel sheet (or something) > (2) use this list to generate a bunch of insert statements for the > users table in sipxconfig > (3) use same list & sip passwords to generate cli statements for patton
No - you misunderstand. You only need _one_ user, and it does not need to match that of the pbx extensions. It is a single identity for the gateway. > > If you can get the gateway between your legacy pbx and sipXecs to > > authenticate itself (that is, configure a user in sipXecs for the > > gateway and put those credentials in the gateway) it would be much > > better. Note that the user you configure does _not_ need to be the same > > as the identity in the From header for this to work. The From header > > can be the extension on the other pbx and the user the gateway > > authenticates as can be something else entirely - sipXecs doesn't care; > > all it wants is an identity that has the permission required by the dial > > plan. This is a _much_ better approach than removing the permission. > > > > > > > > _______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users