Thanks, that fixed the issue...

On Fri, Feb 5, 2010 at 1:01 AM, Scott Lawrence <[email protected]>wrote:

> On Thu, 2010-02-04 at 23:17 +1300, Justin Menga wrote:
> > I came across a strange issue with SIPXecs 4.0.4 - if I use the normal
> > Logical AND operator (&&) in a cond element within a prompt field, the
> > VXML interpreter seems to fail.
> >
> > e.g. the below VXML causes the VXML application to stop...
> >
> > <prompt cond="myvalue > 0 && yourvalue < 10">
> >      ...
> > </prompt>
>
>
> > Any ideas on how to get logical AND working?
>
> The '&' character has to be escaped in XML content.  Try:
>
> <prompt cond="myvalue > 0 &amp;&amp; yourvalue < 10">
>
>