On Tue, 2010-02-09 at 08:53 -0500, Jeff Gilmore wrote:
> <==I am resending this message, as I never saw it come back on the list==>
> 
> I am testing a new trunk for inbound calling.  Outbound works fine on this 
> trunk.
> 
> When I place a call from the PSTN, the sipx target extension rings 
> immediately.  However, the call does not connect for another 10 seconds or 
> so.  
> 
> I have attached a trace of a call that went like this:
> 
> 1. Placed call from an outside phone (i.e not attached to my switch).
> 2. The sipx extension which has the called DID as an alias rings immediately.
> 3. I pick up after 1 ring.
> 4. I hear dead air on both phones (and no ringing, or ring tone on either).
> 5. After about 10 seconds, I hear a brief ring tone on the calling phone.
> 6. The audio connects,
> 7. I stay on the line for about 10 seconds.
> 8. I hang up the sipx extension
> 
> That extension is a Linksys SPA2102 (although the behavior was similar
> when I routed the DID to a Polycom 320).  On either device, a call
> placed from another sipx extension connects normally.
> 
> Would any of you angels of mercy out there be willing to read the
> trace and see if you can tell why it does not respond immediately when
> the extension goes off-hook?

Since there's no indication in that trace of the exact time that the
phone went off hook, there's really no way to answer that.  The timing
of the messages does not look remarkable.


_______________________________________________