I have not found a way to modify CLI in the Audiocodes platform. This 
would be a nice thing to know if someone has figured this out.

Josh Patten
Assistant Network Administrator
Brazos County IT Dept.
(979) 361-4676


On 5/6/2010 12:24 PM, Eelco Brölman wrote:
> Hi all,
>
> I just installed a Mediant 1000 gateway, uploaded the generated config for it 
> (pretty standard), and that works like a charm. But: when a call comes in 
> from the PSTN to the gateway with a CLI which is the same as a user defined 
> in sipXecs, then sipXecs will ask for 407 proxy authentication, which the 
> Mediant obviously cannot provide.
>
> I know having users with the same ID as possible incoming CLI's does not make 
> much sense in a real deployment, but this is a test-platform in which it is 
> that way.
>
> 2 questions:
>
> 1) Does this sounds like a bug, or is sipXecs designed this way (matching 
> from:/contact: address before matching on a configured gateway)
>
> 2) As a workaround, I can define a prefix in the Mediant web interface to add 
> to the incoming CLI's, which obviously works (in the web interface: Protocol 
> Configuration =>  Manipulation Tables =>  Source Number Tel->IP). This is 
> kind of a solution, the question remains if these setting can be done from 
> the sipXecs configuration, otherwise I have to manually configure the Mediant.
>
> Kind regards,
>
> Eelco Brölman
>
> -----
> Eelco Brölman | Sr. Product Specialist | Telecats bv
>
> _______________________________________________
> sipx-users mailing list [email protected]
> List Archive: http://list.sipfoundry.org/archive/sipx-users
> Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users
> sipXecs IP PBX -- http://www.sipfoundry.org/
>    
_______________________________________________
sipx-users mailing list [email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users
Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users
sipXecs IP PBX -- http://www.sipfoundry.org/

Reply via email to