You need to make sure sipx domain lists ONLY your valid intranet subnets. By
default it lists three large subnets. If sipx talks to the provider on
10.x.x.x and goes through NAT, you need to remove 1he 10.0.0.0 subnet and
address this first. If it does not think it is talking via NAT it will send
it's internal address via sipxrelay (the media relay function). The subnets
page is where that is determined.

On Tue, Jul 27, 2010 at 3:40 AM, Irena Dolovčak <[email protected]>wrote:

> Hi,
> I have a problem configuring sipx with my sip trunk provider..
> I just can't make it work.. If somebody would have a hint for me I would be
> so grateful..
>
> Here is the situation:
> I have the sipx on my lan (192.168.1.6), I have an Snom 300 phone
> (192.168.1.10 - registered as 200 on sipx)
> there is a mikrotik router 750G. it connects to the sip trunk provider
> (optima). his ip address is 10.160.250.62, the gateway to the provider is
> 10.160.250.61; and the sip gateway to which the sipx should dial is
> 10.160.4.146..
> this connection is on routers interface ether3;
> on routers interface ether1 is the pppoe client which has a static ip..
> 89.201.77.22 (it's not the real ip here).
> so. there is a firewall on the router, with NAT.
> The thing is.. i'm not sure if a have configured all the parameters..
>
> the phone cannot make a call.. it gets ITSP timed out..
> i can see the packets are going to the provider, and I asked them if they
> get any packets.. they said, that they get packets with the local ip of my
> server. which has confused me.. because i have put 10.160.250.62 to be the
> public IP address. then i changed it to 89.201.77.22.. but still the same..
> what am i doing wrong? any ideas?
>
> i have attached the logs from sipx and phone..
>
> thanks to everyone..
>
> --
> Irena Dolovčak
>
> _______________________________________________
> Sipx-users mailing list
> [email protected]
> List Archive: http://list.sipfoundry.org/archive/sipx-users/
>



-- 
======================
Tony Graziano, Manager
Telephone: 434.984.8430
sip: [email protected]
Fax: 434.984.8431

Email: [email protected]

LAN/Telephony/Security and Control Systems Helpdesk:
Telephone: 434.984.8426
sip: [email protected]
Fax: 434.984.8427

Helpdesk Contract Customers:
http://www.myitdepartment.net/gethelp/

Why do mathematicians always confuse Halloween and Christmas?
Because 31 Oct = 25 Dec.
_______________________________________________
Sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/

Reply via email to