I don't recall that ever being in the defaults.
============================
Tony Graziano, Manager
Telephone: 434.984.8430
Fax: 434.984.8431

Email: [email protected]

LAN/Telephony/Security and Control Systems Helpdesk:
Telephone: 434.984.8426
Fax: 434.984.8427

Helpdesk Contract Customers:
http://www.myitdepartment.net/gethelp/

----- Original Message -----
From: [email protected]
<[email protected]>
Cc: [email protected] <[email protected]>
Sent: Wed Aug 04 16:36:26 2010
Subject: Re: [sipx-users] ACD Broken with NAT enabled on 4.2.1

>>> "Matt White" <[email protected]> 08/04/10 2:05 PM >>>
>>> Tony Graziano <[email protected]> 08/04/10 1:54 PM >>>
>>>do all the lines on the phone register?
>>
>>Yup, and calling to external and internal  numbers, inbound external
>>calls, transfers and even hairpins work as >>expected.
>>
>>So far its only the ACD I can see that is failing.

So after looking into the trace a bit more I see the acd send an IP of
127.0.0.2 in the invite.  So I think to myself....hmmm i wonder if it thinks
127.0.0.2 is not a local network.

Add 127.0.0.0/24 to the list of local subnets and bingo!  Works great.

I can't see any harm with that setting, in fact wasn't that default for the
longest time?

I need to go check one of our older ACD clients to check the subnet setting
to see what older versions used. Of course alot of our older customers use
ingates and do not use the nat function at all.