No. On incoming calls (from PSTN to sipx) the gateway would not be ANY, it would be NONE. Sipx would be the gateway.
You only choose an actual gateway or SBC when you want that gateway to pass the call on (out to PSTN or remote network/system). I think those type of dial plans should be specific and also carefully placed in the dial plan to prevent real calls from "not" getting out. On Wed, Sep 15, 2010 at 4:41 PM, Stiles Watson <[email protected]>wrote: > > Content-Type: text/plain; > charset="utf-8" > Content-Transfer-Encoding: 8bit > Organization: SipXecs Forum > In-Reply-To: <[email protected]> > X-FUDforum: 08063afcdd00a6e76393c5b9527381e8 <52001> > Message-ID: <[email protected]> > > > > I believe the correct way to handle incoming call routing > based on number dialed is through custom dial-plans: > > > Go to System-->Dial Plans then under the "Add New Rule" > drop-down select "Custom" > check "Enabled" > Give it a descriptive name > If no part of the number contains the extension you want to > forward the call to, enter the entire number as the "Prefix" > under "Dialed Number" and leave the number of digits > drop-down set to "0 digits" > Do not check anything under "Required Permissions" > In the "Dial" text box under "Resulting Call" enter the > extension you want dialed (could be an Auto Attendant) and > append "Nothing" > Under "Gateways", select the gateway this call comes in on > from the "More actions..." drop-down > Click "OK" > > > The above works if you want a DID such as 1-234-555-5555 to > route to extension 100. Just enter 12345555555 as the > "Prefix" and 100 in the "Dial" text box. > > However, if the last 3 digits of 1-234-555-5555 are the > extension, you would enter 12345555 as the "Prefix", select > "3 digits" in the drop-down, leave "Dial" empty and select > "Matching suffix" from the append drop-down under "Resulting > Call". > > Hope that makes sense. > > Stiles > _______________________________________________ > sipx-users mailing list > [email protected] > List Archive: http://list.sipfoundry.org/archive/sipx-users/ > -- ====================== Tony Graziano, Manager Telephone: 434.984.8430 sip: [email protected] Fax: 434.984.8431 Email: [email protected] LAN/Telephony/Security and Control Systems Helpdesk: Telephone: 434.984.8426 sip: [email protected] Fax: 434.984.8427 Helpdesk Contract Customers: http://www.myitdepartment.net/gethelp/ Why do mathematicians always confuse Halloween and Christmas? Because 31 Oct = 25 Dec.
_______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users/