Hi All,
I'm doing some experimenting with some different call routing scenarios and have run into an issue. Sipx 4.2.1 installed from ISO with a Polycom 300 and Grandstream GXP2020 phones connected for testing. Having been testing for a while and everything has been working very well. Had my ITSP connected via B2BUA with sipXbridge and incoming/outgoing calls were fine. I changed the SIP Trunk Gateway that was pointing to my ITSP and pointed it to a Freeswitch server that I am running - just to test some ideas. The Freeswitch server has a public IP and listens on port 5090. I have the "Address" and "Port" fields pointing to my Freeswitch IP and 5090 in the main Gateway configuration page and I have "<FS_IP_ADDRESS>:5090>" set under the "ITSP Account" settings of the Gateway. Sipx is registered to my Freeswitch server via sipXbridge. "Long Distance" Dial Plan is enabled and configured to use my Gateway. When I try to place a call from a phone - I get back a "500 Internal Server Error". A packet capture shows that the phone sends an Invite to sipX, sipX returns "100 Trying" and then returns "500 Server Internal Error, with sipfrag". The Message Body of the packet says "Sipfrag" and "Exception Info Unexpected error creating INVITE at Siputilities.java:839" I have googled this error, but not finding any info. Anyone have any ideas? Thanks, Dave Redmore
_______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users/