________________________________________ From: [email protected] [[email protected]] On Behalf Of David Becker [[email protected]]
Hm, closer inspection reveals that the Siemens phone doesn't send an algorithm=md5 parameter. Also the contact address is doubled, is that problematic? Am 20.10.2010 10:53, schrieb David Becker: > I found this in the sipstatus.log: > "2010-10-20T08:46:36.635044Z":756:AUTH:DEBUG:test.voip.ikt-bs.de:SubscribeServerThread:B6D61B90:SipStatus:"SubscribeServerThread::isAuthenticated() > - No Credentials for > mailboxUrl=\"<sip:[email protected]:5060>;transport=udp\", > reqRealm=\"test.voip.ikt-bs.de\", reqUser=\"203\"" > > Does that mean the credentials are wrong or that it's not supplying the > parts it needs for an MWI subscription? ________________________________________ I haven't checked, but I'm 99% certain that algorithm=md5 is the default. But I see that the supposed mailboxUrl is "<sip:[email protected]:5060>;transport=udp", which isn't a URI, so there's a good chance that the SUBSCRIBE being sent by the phone is incorrect. Dale _______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users/