________________________________________
From: [email protected] 
[[email protected]] On Behalf Of David Becker 
[[email protected]]

Hm, closer inspection reveals that the Siemens phone doesn't send an
algorithm=md5 parameter. Also the contact address is doubled, is that
problematic?

Am 20.10.2010 10:53, schrieb David Becker:
>    I found this in the sipstatus.log:
> "2010-10-20T08:46:36.635044Z":756:AUTH:DEBUG:test.voip.ikt-bs.de:SubscribeServerThread:B6D61B90:SipStatus:"SubscribeServerThread::isAuthenticated()
> - No Credentials for
> mailboxUrl=\"<sip:[email protected]:5060>;transport=udp\",
> reqRealm=\"test.voip.ikt-bs.de\", reqUser=\"203\""
>
> Does that mean the credentials are wrong or that it's not supplying the
> parts it needs for an MWI subscription?
________________________________________

I haven't checked, but I'm 99% certain that algorithm=md5 is the default.  But 
I see that the supposed mailboxUrl is 
"<sip:[email protected]:5060>;transport=udp", which isn't a URI, so 
there's a good chance that the SUBSCRIBE being sent by the phone is incorrect.

Dale