On 12/2/2010 1:11 PM, M. Ranganathan wrote:
> Hello all,
>
> Is anybody using bandwidth.com trunks? What is their SIP address? I
> just tested and much to my surprise, found I could not resolve that
> name.
>
> Has this changed?
>
> Thanks
>
> Ranga
>
This is what they sent me for one trunk I did.

PBX Configurations required for Bandwidth.com SIP Trunks:
• Please turn off registrations and any SIP username/password—they are 
not required and will hinder functionality. (except Switchvox and 
Altigen PBX's)
• Bandwidth.com Primary inbound gateway IP: 216.82.224.202 port 5060 SIP/UDP
• Bandwidth.com Secondary inbound gateway IP: 216.82.225.202 port 5060 
SIP/UDP
• Bandwidth.com Primary outbound gateway IP: 216.82.224.202 port 5060 
SIP/UDP
• Bandwidth.com Secondary outbound gateway IP: 216.82.225.202 port 5060 
SIP/UDP
• DTMF: RFC2833
• Supported Codecs: G.711Ulaw and G.729A
• SIP REFER is not supported, please use SIP REINVITE
• Inbound and Outbound Numbers can be formatted in the following formats: