On 12/2/2010 1:11 PM, M. Ranganathan wrote: > Hello all, > > Is anybody using bandwidth.com trunks? What is their SIP address? I > just tested and much to my surprise, found I could not resolve that > name. > > Has this changed? > > Thanks > > Ranga > This is what they sent me for one trunk I did.
PBX Configurations required for Bandwidth.com SIP Trunks: • Please turn off registrations and any SIP username/password—they are not required and will hinder functionality. (except Switchvox and Altigen PBX's) • Bandwidth.com Primary inbound gateway IP: 216.82.224.202 port 5060 SIP/UDP • Bandwidth.com Secondary inbound gateway IP: 216.82.225.202 port 5060 SIP/UDP • Bandwidth.com Primary outbound gateway IP: 216.82.224.202 port 5060 SIP/UDP • Bandwidth.com Secondary outbound gateway IP: 216.82.225.202 port 5060 SIP/UDP • DTMF: RFC2833 • Supported Codecs: G.711Ulaw and G.729A • SIP REFER is not supported, please use SIP REINVITE • Inbound and Outbound Numbers can be formatted in the following formats: _______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users/