On 1/27/11 9:14 PM, Michael Scheidell wrote:
sipx->diagnosics,-> show registrations doesn't show it either.
so, its NOT a 4 line phone!
no, found the trick.
if I look at the phone on its GUI, it wants a different local port per line.
line 1, 5060
line 2, 5062,
line 3, 5064,
line 4, 5066
I went to sipx config for the user->phone->line[2] changed sip port to
5062, then line[3], 5064. boot up, its a 4 line phone now.
--