I think you have a misunderstanding on the configuration of the Audiocodes
devices.  They are not auto provisioning.  They are managed, in that they
have a template that has been prepared for them.  However, you have to move
the INI file that is created by that template to the device yourself, as it
appears you are now doing.

I've had a similar problems with some trunks not disconnecting, which I
could not correct in the configurations that are created by sipXecs.  

There is a ton of optional configurations in the Audiocodes that is accessed
via another web interface on the units that is hidden.  In there is a
configuration for adjusting the voltage level for detection.  I've had to
play with it at times to get disconnect to work correctly.  Unfortunately, I
don't have my notes on that with me at this time, but your Distributor
Support can probably get you the details.   Look for a parameter for Current
Level.

-----Original Message-----
From: [email protected]
[mailto:[email protected]] On Behalf Of Mike Haun
Sent: Monday, April 04, 2011 4:21 PM
To: [email protected]
Subject: Re: [sipx-users] AC MP-114 FXO auto provisioning problem


Content-Type: text/plain;
  charset="utf-8"
Content-Transfer-Encoding: 8bit
Organization: SipXecs Forum
In-Reply-To: <[email protected]>
X-FUDforum: 08063afcdd00a6e76393c5b9527381e8 <58376>
Message-ID: <[email protected]>



Has there been any resolution to this?  I've had the exact
same problem and can't figure it out.

I'm running Sipx 4.2.1-018971 with the AudioCodes MP-114 FXO
5.80A firmware.  I cannot get sipx to send the configuration
to the MP114 even though it is suppose to.  I have saved the
.ini file to my local drive then have uploaded it to the AC
device via it's web interface and that seems to work fine
for that part, but...

The biggest problem that is driving me crazy is that I
cannot get it to disconnect if the PSTN hangs up first! 
I've tried polarity reversal and current disconnect but
neither of them work.  Very frustrating.

If anyone has a good progress tones file that works with
POTS lines from AT&T then I would really like to try that. 
Thanks.


_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/

_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/

Reply via email to