I have Sipx 4.2.1 running for a client and they've been very happy for about a year. I just switched sip providers from A to B. The only thing I had to change in my sipx configs was the IP address of of the SIP Trunk gateway.
Here's the odd thing: Test 1 A call comes in and finds it's path in a dial plan which is a custom type DP that has an extension number (6302) in the "Resulting Call" field. Ext 6302 does not have a phone but it's Call Forwarding parameters are set to ring first for 1 second, then if no response forward to <an outside number>. It forwards the call just fine, but there is NO AUDIO in either direction! Test 2 Now, another call comes in and it's dial plan sends it to an AutoAttendent and since the caller knows the extension number they dial 6302 which sends the call to extension 6302 which forwards to <an outside number> as in Test 1, but using this method it is a crystal clear connection with both way audio! I've looked everywhere within Sipx configs to see if I had two places where the IP address needed changed, but I only found the one place at Devices -> Gateways -> Sip Trunk Gateway -> Address. I cannot figure this out and am hoping you will provide me with some guidance. Thank you.
_______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users/