Just checking, do you have good luck with these phones? I believe they were discontinued and I tried out the 7800. I had horrible problems with it and couldn't find any decent documentation. There were spelling mistakes on the LCD menus as well. I didn't realize until this post that any support for Unidata phones had been added to sipx.

On 5/22/2011 3:30 PM, Peter van der Salm wrote:
Hi All,

The current phone plug in for the Unidata WPU-7700 phone does not work in 4.4.0 
of 2011-04-19.
The .jar file is not the correct version.

To solve this do the following:

# cd /usr/share/java/sipXecs/sipXconfig
# mv unidata-phones.jar unidata-phones.jar.old

and copy the attached unidata-phones.jar into /usr/share/java/sipXecs/sipXconfig

If you use the standard template settings, I strongly suggest to set the sip 
timers to either 0 (=off) or to much longer values than the current 500 msec. 
Actually they should be something like 64 times the expected roundtrip time for 
the phone, which could be quite long due to power saving in the WiFi.

Good luck!

Peter van der Salm












_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/

_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/

Reply via email to